Download Free Cooper Security Insert Manual Page

Posted on by

• Security System Installation Guide. • Every effort has been made to ensure that the contents of this book are correct.

However, neither the authors nor Cooper Security Limited accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book. The contents of this book are subject to change without notice. • CONTENTS Outputs.23 Fuses.23 Electrical Safety. Introduction.1 Compliance Statements. 23 Communications. 1 Compatible Equipment.24 Level Setting or Partitioned System.1 2. Before You Begin.2 Preparation.

Download Free Cooper Security Insert Manual Page

Preview Universal Security Instruments Ionization 5304 User's Manual Page 5 Online and Download PDF. Universal Security Instruments 5304 for free. View and Download Cooper Security I-on 16 installation and programming manual online. Use the u or n keys to highlight a free zone and press. Download free 1990 audi 100 strut insert manual. User Manuals, Instructions and Guides. Download user manual for the. Blog Tool, Publishing Platform, and CMS — Word.

2 Siting the Unit. A New Ladder Of Citizen Participation Pdf Printer here. 2 Guided Tour. • i-on40 This page is intentionally blank. • i-on40 8750 An Ethernet module that allows 1.

Introduction alarm reporting and remote maintenance over the internet. The i-on40 is the control unit for a hybrid 8844 A GPRS module that allows wired/wirefree alarm system intended for internet protocol access over the domestic and light commercial use. • To do this you should conduct signal strength tests.

Cooper Security produce the Scantronic 790r hand held signal strength meter for this purpose. Alternatively, you can power the control unit from a battery. Siren test output (not used in UK). Printed circuit board (PCB). Cable entry holes for detector and keypad Keypad Controls and Displays wiring.

Mains connector block. Cable entry hole for mains. Back Tamper switch (if fitted). End Station PCB 2 abc 3 def. • i-on40 Power Availability Before connecting any external devices to the control unit, you must make sure that the control unit can provide sufficient current to power the system during a mains failure for the time required to meet Grade 2 PD6662 or EN50131-1. 03 Adolescence Lyrics Clean Up Woman there.

The amount of current available from the control unit depends on the battery fitted. • Figure 9 Fixing Holes and Cable Entries Figure 10 Screw Keypad Back Box to Wall 1. Tomtom Karte Central Europe Download Movies more. Fixing holes.

Cable entries. Cooper Security recommend that you use at least four fixing holes when mounting Page 5. • i-on40 Star Daisy Chain Connecting Keypads to End Station Cable Type In general, the control unit requires standard 7/0.2 un-screened four core alarm cable for wiring to keypads.

Terminate For maximum performance in harsh environments use twisted pair cable with a MENU 2 abc 3 def. • i-on40 control unit and 5 in Fig 8 for the keypad).

ABCD-ON Fitting a jumper to the pins adds a MENU termination to the cable. 2 abc 3 def 4 ghi 5 jkl 6 mno 7 pqrs 8 tuv 9 wxyz In a daisy chain configuration terminate each end of the chain (see Fig 11 ). • i-on40 Mains Cabling Step 4. Connect Wired Make sure that the mains supply cable does Zones not run vertically behind the aerials within the end station case.

Four Wire Closed Circuit Connections If you wish run mains cable through the side of the case, make sure that they are horizontal for the last metre before entering the case. • i-on40 Step 5. Connect Wired Peripherals 100 Ohms 12V + Tamper In Tamper Out Strobe +ve Strobe -ve Alarm contacts Trigger -ve 2K2 EOL Zone 2 Tamper contacts Zone 1 Alarm contacts 2K2 EOL Tamper contacts Alarm contacts Alarm contacts Zone 1 2K2 EOL Tamper contacts. • i-on40 Step 6. Fit a Plug-By If the system has already been installed: 4.